Refine your search:     
Report No.
 - 
Search Results: Records 1-10 displayed on this page of 10
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Establishment of a novel detection system for measuring primary knock-on atoms

Tsai, P.-E.; Iwamoto, Yosuke; Hagiwara, Masayuki*; Sato, Tatsuhiko; Ogawa, Tatsuhiko; Satoh, Daiki; Abe, Shinichiro; Ito, Masatoshi*; Watabe, Hiroshi*

Proceedings of 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2017) (Internet), 3 Pages, 2018/11

The energy spectra of primary knock-on atoms (PKAs) are essential for radiation damage assessment in design of accelerator facilities. However up to date the experimental data are still limited, due to the poor mass resolution and the high measurement threshold energies in the conventional setup of nuclear physics experiments using solid state detectors, which are typically above a few MeV/nucleon. In this study, a novel detection system consisting of two time detectors and one dE-E energy detector is proposed and being constructed to measure the PKA spectra. The system and detector design was based on Monte Carlo simulations by using the PHITS code. The PHITS simulations show that the system is able to distinguish the PKA isotopes above $$sim$$0.2-0.3 MeV/nucleon for A=20$$sim$$30 amu; the PKA mass identification thresholds decrease to $$<$$0.1 MeV/nucleon for PKAs lighter than 20 amu. The detection system will be tested in the summer of 2017, and the test results will be presented at the conference.

Journal Articles

Development of differential die-away technique in an integrated active neutron NDA system for nuclear non-proliferation and nuclear security

Ozu, Akira; Maeda, Makoto; Komeda, Masao; Toh, Yosuke; Koizumi, Mitsuo; Seya, Michio

Proceedings of 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2017) (Internet), 4 Pages, 2018/11

Journal Articles

Delayed gamma-ray spectroscopy inverse Monte Carlo analysis method for nuclear safeguards nondestructive assay applications

Rodriguez, D.; Rossi, F.; Seya, Michio; Koizumi, Mitsuo

Proceedings of 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2017) (Internet), 3 Pages, 2018/11

Journal Articles

Development of radiation resistant monitoring camera system

Takeuchi, Tomoaki; Otsuka, Noriaki; Watanabe, Takashi*; Tanaka, Shigeo*; Ozawa, Osamu*; Komanome, Hirohisa*; Ueno, Shunji*; Tsuchiya, Kunihiko

Proceedings of 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2017) (Internet), 3 Pages, 2018/11

no abstracts in English

Journal Articles

Evaluation of in-water wireless transmission system under the conditions simulated the severe accident

Otsuka, Noriaki; Takeuchi, Tomoaki; Tsuchiya, Kunihiko; Shibagaki, Taro*; Komanome, Hirohisa*

Proceedings of 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2017) (Internet), 3 Pages, 2018/11

no abstracts in English

Oral presentation

Optimization a thickness of GAGG scintillator for detecting plutonium in a field of high beta and gamma background

Morishita, Yuki; Yamamoto, Seiichi*; Izaki, Kenji; Kaneko, Junichi*

no journal, , 

Spectroscopy of alpha particles is necessary to distinguish plutonium isotopes from radon progeny. We previously developed an alpha particle imaging detector by combining a 0.1-mm-thick GAGG scintillator with a silicon photomultiplier (SiPM). This detector had better energy resolution than the ZnS(Ag) scintillator-based alpha particle detector. However, it had $$beta$$ or $$gamma$$ sensitivity because the GAGG scintillator was too thick compared with the range of 5.5 MeV $$alpha$$ particles. Therefore, it is difficult to measure alpha particles from plutonium in a field with high $$beta$$ and $$gamma$$ background. To solve this problem, we optimized the thickness of GAGG scintillator by comparing three GAGG scintillators with thicknesses of 0.05 mm, 0.07 mm, and 0.1 mm. Each of the GAGG scintillators was optically coupled to SiPM, which was used as the photodetector. The peak channels and energy resolutions for 5.5 MeV alpha particles of three GAGG scintillators were compared. Also, the count rates of $$beta$$ particles of the GAGG scintillators were evaluated by using a $$^{90}$$Sr source. The peak channel of the 0.05-mm-thick GAGG scintillator was 1.6x higher than that of the 0.1-mm-thick GAGG scintillator and 3.7x higher than that of the plastic scintillator. The 0.05-mm-thick GAGG scintillator had the best energy resolution of 11.6 % FWHM and the lowest $$beta$$ count rate of 0.2 cpm among the three GAGG scintillators.

Oral presentation

Development of an alpha particle spectrometer based on a GPS scintillator plate based for high-reliable dust monitor

Morishita, Yuki; Kaneko, Junichi*; Izaki, Kenji; Yajima, Tatsuo*; Matsuura, Mitsugu*

no journal, , 

For detecting airborne contamination of $$^{238}$$Pu and $$^{239}$$Pu released by the accident, a dust monitor with a silicon surface barrier detector (SSBD) is introduced at a site of nuclear fuel facility. However, SSBD frequently produces a false alarm triggered by an electromagnetic noise generator. For high-reliable dust monitoring, we developed an $$alpha$$ particle spectrometer based on the GPS scintillator plate with PMT. Our developed spectrometer consists of a cerium doped Gd$$_{2}$$Si$$_{2}$$O$$_{7}$$ (GPS) scintillator plate and a Photomultiplier Tube (PMT). The GPS scintillator plate was hexagonal in shape and 50 mm in diameter and a scintillator layer was approximately 40 um. An $$^{241}$$Am source with 5.5 MeV $$alpha$$ particle, Rn progeny collected air filter, and PuO$$_{2}$$ particle were measured by developed spectrometer. The energy resolution for 5.5-MeV $$alpha$$ particles was 11.9% FWHM. The radon progeny nuclide reduction ratio (Rratio) was improved compared with ZnS(Ag) based $$alpha$$ spectrometer, so that Pu and Rn progeny can be effectively distinguished. Thus, our developed $$alpha$$ spectrometer will be high-reliable dust monitor for detecting Pu contamination.

Oral presentation

A Two-dimensional scintillation neutron detector module for a new protein single crystal neutron diffractometer at J-PARC MLF

Nakamura, Tatsuya; To, Kentaro; Tsutsui, Noriaki; Ebine, Masumi; Birumachi, Atsushi

no journal, , 

A position-sensitive scintillation detector module for a new protein neutron diffractometer was developed by using a scintillator / wavelength shifting (WLS) fiber technology. The detector module has a spatial resolution of 2.5 mm with a neutron-sensitive area of 320 $$times$$ 320 mm$$^{2}$$. The WLS fibers are arranged in a regular pitch of 2.5 mm in x and y direction and those arrays are placed diagonally. The light reflecting grid is inserted in between the fibers in order for optical isolation and for mechanical support of the fiber. The detector implemented flat $$^{6}$$Li/ZnS screens up and downstream of the WLF fiber arrays. The detector exhibited a detection efficiency of 30-50% for thermal neutron (depending on $$gamma$$-ray sensitivities) and a count uniformity of ~13%. In this paper detailed detector design and experimental results obtained using a pulsed neutron beam are presented.

Oral presentation

Compact Compton camera for radiation distribution imaging under high dose rate environments

Sato, Yuki; Terasaka, Yuta; Kaburagi, Masaaki; Tanifuji, Yuta; Usami, Hiroshi; Miyamura, Hiroko; Ozawa, Shingo*; Izumi, Ryo*; Kawabata, Kuniaki; Suzuki, Toshikazu*; et al.

no journal, , 

Oral presentation

A Micro pixel chamber based neutron imaging detector ($$mu$$ NID) with boron converter for energy-resolved neutron imaging at J-PARC

Parker, J. D.*; Shinohara, Takenao; Harada, Masahide; Hayashida, Hirotoshi*; Hiroi, Kosuke; Kai, Tetsuya; Matsumoto, Yoshihiro*; Oikawa, Kenichi; Segawa, Mariko; Su, Y. H.; et al.

no journal, , 

10 (Records 1-10 displayed on this page)